hit counter script

Displaying The Hardware Inventory For A Switch; Displaying The Backplane And Serial Number Information - Cisco Nexus 9508 Hardware Installation Manual

Nx-os mode switch
Hide thumbs Also See for Nexus 9508:
Table of Contents

Advertisement

Managing the Switch
CLEI code is
switch#

Displaying the Hardware Inventory for a Switch

You can display information about the field replaceable units (FRUs), including product IDs, serial numbers,
and version IDs by using the show inventory command. The output for this command displays information
about modules that respond to command line interface commands, such as supervisors, system controllers,
line cards, fans, fabric modules, and power supplies, but not to modules that do not respond to those commands,
such as blank modules that cover empty slots to manage airflow.
switch# show inventory
NAME: "Chassis",
PID: N9K-C9508
NAME: "Slot 4",
PID: N9k-X9636PQ
NAME: "Slot 22",
PID: N9K-C9508-FM
NAME: "Slot 24",
PID: N9K-C9508-FM
NAME: "Slot 26",
PID: N9K-C9508-FM
NAME: "Slot 27",
PID: N9K-SUP-A
NAME: "Slot 28",
PID: N9K-SUP-A
NAME: "Slot 29",
PID: N9K-SC-A
NAME: "Slot 30",
PID: N9K-SC-A
NAME: "Slot 33",
PID: N9K-PAC-3000W-B
NAME: "Slot 36",
PID: N9K-PAC-3000W
NAME: "Slot 41",
PID: N9K-C9508-FAN
NAME: "Slot 42",
PID: N9K-C9508-FAN
NAME: "Slot 43",
PID: N9K-C9508-FAN
switch#

Displaying the Backplane and Serial Number Information

You can display the backplane information, including the serial number for the switch by using the show
sprom backplane command.
DESCR: "Nexus9000 C9508 (8 Slot) Chassis "
,
VID: V01 ,
SN: SAL17257PBN
DESCR: "36p 40G Ethernet Module"
,
VID:
,
SN: SAL17257AHD
DESCR: "Fabric Module"
,
VID: V01 ,
SN: SAL17194HVX
DESCR: "Fabric Module"
,
VID: V01 ,
SN: SAL17194HRK
DESCR: "Fabric Module"
,
VID: V01 ,
SN: SAL17194HSR
DESCR: "Supervisor Module"
,
VID: V01 ,
SN: SAL17184072
DESCR: "Supervisor Module"
,
VID: V01 ,
SN: SAL1739DAUL
DESCR: "System Controller"
,
VID:
,
SN: SAL17225YFS
DESCR: "System Controller"
,
VID:
,
SN: SAL17225YG8
DESCR: "Nexus9000 C9508 (8 Slot) Chassis Power Supply"
,
VID: V01 ,
SN: DTM1722000A
DESCR: "Nexus9000 C9508 (8 Slot) Chassis Power Supply"
,
VID: V01 ,
SN: DTM164601XC
DESCR: "Nexus9000 C9508 (8 Slot) Chassis Fan Module"
,
VID: V01 ,
SN: SAL171843HG
DESCR: "Nexus9000 C9508 (8 Slot) Chassis Fan Module"
,
VID: V01 ,
SN: SAL171843K2
DESCR: "Nexus9000 C9508 (8 Slot) Chassis Fan Module"
,
VID:
,
SN: SAL171421SY
Cisco Nexus 9508 NX-OS Mode Switch Hardware Installation Guide