4
Parts Replacement and Clearning > Fixing > Cleaning the Fixing Inlet Guide,Fixing Inlet Sensor Flag, Fixing Right Stay, Dowel, Dowel Holder
Cleaning the Fixing Inlet Guide,Fixing Inlet Sensor
Flag, Fixing Right Stay, Dowel, Dowel Holder
<Preparation>
1. Pull out the Fixing Feed Unit. (Refer to "Removing the Fixing Assembly")
2. Remove the Fixing Assembly. (Refer to page 4-173)
<Procedure>
1) Clean the Fixing Inlet Guide with lint-free paper moistened with alcohol.
2)Clean the Fixing Right Stay, Dowel, Dowel Holder with lint-free paper moistened with
alcohol.
4
Parts Replacement and Clearning > Fixing > Cleaning the Fixing Inlet Guide,Fixing Inlet Sensor Flag, Fixing Right Stay, Dowel, Dowel Holder
3) Remove the Fixing Inlet Guide Unit.
•
1 Connector
•
2 Wire Saddles
•
1 Harness Guide
•
2 Screws
CAUTION:
When removing the Fixing Inlet Guide Unit, be careful no to turn the 2 Adjustment
Screws.
F-4-310
4-175
F-4-311
x3
F-4-312
4-175