Alarm
Title
Code
10-0007
Patch Sensor error 2
Movement: Not update the D-max control value.
Cause: Max-Min of the background is 100 level or higher.
Measures:
1. Clean the Patch Sensor (PS90).
2. Check the connector connection of the Patch Sensor (PS90).
Sensor: J2143, Relay: J3255, J3060, J3177, Main Driver
PCB (PCB2): J107
3. Check the connector connection of the Patch Sensor Shutter
Solenoid (SL10).
Sensor: J2143, Relay: J3249, J3060, J3177, Main Driver
PCB (PCB2): J107
4. Replace the Patch Sensor (PS90).
5. Replace the Patch Sensor Shutter Solenoid (SL10).
6. Replace the Patch Shutter.
10-0008
Patch Sensor error 3
Movement: Not update the D-max control value.
Cause: Patch density for condition 0 is 970 or higher.
Measures:
1. Clean the Patch Sensor (PS90).
2. Check the connector connection of the Patch Sensor (PS90).
Sensor: J2143, Relay: J3255, J3060, J3177, Main Driver
PCB (PCB2): J107
3. Check the connector connection of the Patch Sensor Shutter
Solenoid (SL10).
Sensor: J2143, Relay: J3249, J3060, J3177, Main Driver
PCB (PCB2): J107
4. Replace the Patch Sensor (PS90).
5. Replace the Patch Sensor Shutter Solenoid (SL10).
6. Replace the Patch Shutter.
10-0009
Patch Sensor error 4
Movement: Not update the D-max control value.
Cause: Patch density for condition 4 is 400 or lower.
Measures:
1. Clean the Patch Sensor (PS90).
2. Check the connector connection of the Patch Sensor (PS90).
Sensor: J2143, Relay: J3255, J3060, J3177, Main Driver
PCB (PCB2): J107
3. Check the connector connection of the Patch Sensor Shutter
Solenoid (SL10).
Sensor: J2143, Relay: J3249, J3060, J3177, Main Driver
PCB (PCB2): J107
4. Replace the Patch Sensor (PS90).
5. Replace the Patch Sensor Shutter Solenoid (SL10).
6. Replace the Patch Shutter.
7
Error Code > Alarm Code > List of Alarm Code
A. movement /B. cause /C. measures
7
Error Code > Alarm Code > List of Alarm Code
Alarm
Title
Code
10-0010
D-max control contrast
Movement: Vcont of D-max control is between 150V and 270V,
potential (Vcont) error
1
Cause: Vcont calculated with D-max control is less than 150V.
Measures:
If density of output image is sufficient, measures are not
needed.
When the density is light (dark), execute PASCAL.
If the problem is not corrected, check/replace the Developing
Assembly.
10-0011
D-max control contrast
Movement: Vcont of D-max control is between 150V and 270V,
potential (Vcont) error
2
Cause: Vcont calculated with D-max control is greater than
270V.
Measures:
If density of output image is sufficient, measures are not
needed.
When the density is light (dark), execute PASCAL.
If the problem is not corrected, check/replace the Developing
Assembly.
10-0012
D-max control contrast
Movement: Vcont of D-max control is between 150V and 270V,
potential (Vcont) error
3
Cause: Difference of Vcont from its of the last D-max control is
50V or higher.
Measures:
If density of output image is sufficient, measures are not
needed.
When the density is light (dark), execute PASCAL.
If the problem is not corrected, check/replace the Developing
Assembly.
11-0002
Waste Toner
Movement: A message "The waste toner container is full." is
Container full
(Photosensitive Drum)
Cause: The Waste Toner Counter reaches 600000.
Measures: Clean the Waste Toner Container. Reset the Waste
A. movement /B. cause /C. measures
and correction amount at a time is 50V or less.
and correction amount at a time is 50V.
and correction amount at a time is 50V or less.
displayed on the Control Panel, and the machine is
stopped.
Toner Counter.
7-97