Symptom

Stained image due to the separation claw contacting with the ETB

[Inspected by Canon Inc. ]
Description
With the machines from among those having serial numbers earlier than the numbers shown in the table
below, stained image occurred because the separation claw in the AP kit assembly [1] came in contact
with the ETB in the ETB assembly [3].
iR-ADV 8105 V2 120V
iR-ADV 8105 V2 230V EUR
iR-ADV 8105 V2 230V
iR-ADV 8105G V2 120V
iR-ADV 8105 V2 220V CN
iR-ADV 8095 V2 120V
iR-ADV 8095 V2 230V EUR
iR-ADV 8095 V2 230V
iR-ADV 8095G V2 120V
iR-ADV 8095 V2 220V CN
iR-ADV 8085 V2 120V
iR-ADV 8085 V2 230V EUR
iR-ADV 8085 V2 230V
iR-ADV 8085G V2 120V
Cause
The separation claw [2] in the AP kit [1] which is installed to prevent paper from go into the drum may
occasionally come in contact with the ETB [4] upon a poor paper separation because the range of
movement of the separation claw is wide. The toner of the transferred image is scraped off by this
contact and the outcome image is stained. Also, when the ETB [4] is damaged or torn completely from
the contact, the image will not be transferred or jam symptoms are induced. The figure [A] shows the
contacting parts.
Model
Serial #
HMU10076
HMW00790
HMX00582
HMV10004
HMY00505
HNA10090
HNC00687
HND00561
HNB10003
HNE00504
HNG10037
HNK00793
HNL00522
HNH10003