free stats

E2820 Braking Resistor Overload Prewarning; E2829 Not Ready For Power On - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

Rexroth IndraDrive

E2820 Braking resistor overload prewarning

Cause
Allowed deceleration of connected drives too high
Energy absorption capacity of braking resistor is
almost exhausted
Regenerated energy in machining cycle is too high
Continuous regenerative power and/or rotary drive
energy is too high

E2829 Not ready for power on

Cause
Resistors for loading DC bus capacitances still are
thermally loaded due to last loading process
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
Supported by Supply Unit:
90% of the energy absorption capacity of the braking resistor have been
reached.
Remedy
Reduce deceleration of connected drives
Switch power off with a delay in the case of OFF or
E-STOP (for regenerative supplies)
Increase cycle time or reduce maximum drive speed of
application
Check dimensioning of braking resistor and, if
necessary, increase dimensioning
E2820 - Attributes
Display:
E2820
Mess. no.:
E2820 (hex)
Supported by Firmware Variant:
The mains voltage for power supply cannot yet be switched on for the
HCS03 converter; the device is not yet ready for loading the DC bus
capacitances.
Remedy
Wait until converter clears warning E2829
E2829 - Attributes
Display:
E2829
Mess. no.:
E2829 (hex)
Warning Diagnostic Messages (Exxxx)
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
8-45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF