A0500 Supply module in voltage control

A0501 Supply module in current control

A0502 Supply module in operation

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Supply Unit:
The mains contactor has been switched in, the DC bus has been
charged, the DC bus voltage is regulated to 750 V direct voltage.
A0500 - Attributes
Display:
Lb
Mess. no.:
A0500 (hex)
Supported by Supply Unit:
The mains contactor has been switched in, the DC bus has been
charged, the DC bus current is regulated with regard to a preset
command value.
Note:
This operating status is only available for manufacturer-side
testing and developing purposes!
A0501 - Attributes
Display:
I Lb
Mess. no.:
A0501 (hex)
Supported by Supply Unit:
The mains contactor has been switched in, the DC bus has been charged
and is ready for power output.
A0502 - Attributes
Display:
Lb
Mess. no.:
A0502 (hex)
Rexroth IndraDrive
HMV01
HMV01
HMV01