C1804 Automatic controller setting failed
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
In exceptional cases difficulties can occur during automatic control loop
setting. This means that automatic setting is impossible and the default or
standard values are loaded to the drive again.
Causes:
• oscillating mechanical systems (resonances)
• highly noisy encoder signals
Remedy:
It is sometimes possible to achieve a satisfactory result by restarting the
command P-0-0162, C1800 Command Automatic control loop adjust
with a high P-0-0163, Damping factor for autom. controller adjust, i.e.
a low degree of dynamic response.
This value then can still be reduced until the desired control loop behavior
occurs.
See also Functional Description "Automatic Setting of Axis Control"