hit counter script

Canon imageRUNNER ADVANCE DX C5870i Service Manual page 661

Hide thumbs Also See for imageRUNNER ADVANCE DX C5870i:
Table of Contents

Advertisement

E747-DF00-00
Detection Description
Remedy
E747-FF00-00
Detection Description
Remedy
E747-FF01-00
Detection Description
Remedy
E748-2000-00
Detection Description
Remedy
E748-2001-00
Detection Description
Remedy
E748-2010-00
Detection Description
Remedy
E748-2011-00
Detection Description
Remedy
Board error
There was unexpected interruption from ASIC.
[Related parts]
- Flat cable betweens the Reader Unit and the Main Controller PCB
- Open I/F PCB (when non-Canon-made controller is installed)
- Main Controller PCB(UN41)
- SSD Unit
[Remedy] Check/replace the related harness/cable, connector and parts.
Board error
There was unexpected interruption from ASIC.
[Related parts]
- Flat cable betweens the Reader Unit and the Main Controller PCB
- Open I/F PCB (when non-Canon-made controller is installed)
- Main Controller PCB (UN41)
- SSD Unit
[Remedy] Check/replace the related harness/cable, connector and parts.
Board error
There was unexpected interruption from ASIC.
[Related parts]
- Flat cable betweens the Reader Unit and the Main Controller PCB
- Open I/F PCB (when non-Canon-made controller is installed)
- Main Controller PCB (UN41)
- SSD Unit
[Remedy] Check/replace the related harness/cable, connector and parts.
Main Controller PCB access error
Main Controller PCB Chip access error.
[Related parts]
- Main Controller PCB
[Remedy] Check/replace the related connector and parts.
Main Controller PCB access error
Main Controller PCB memory access error.
[Related parts]
- Main Controller PCB
[Remedy] Check/replace the related connector and parts.
FLASH PCB error
IPL (startup program) was not found, or the SSD could not be recognized.
[Related parts]
- Cable between the Main Controller PCB and the SSD Unit
- FLASH PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Disconnect the cable between the Main Controller PCB and the SSD Unit, and turn ON the main
power.
a. When the error code has not been changed:
1. Obtain the necessary backup data by referring to the backup data list.
2. After replacing the FLASH PCB, reinstall the system software using SST or a USB memory.
3. Restore the backup data.
b. When the error code has been changed to another one, see the remedy for the corresponding
code.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
FLASH PCB error
OS was not found at startup.
[Remedy]
Replace the FLASH PCB.
649
8. Error/Jam/Alarm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF