COPIER (Service mode for printer) > ADJUST (Adjustment mode) > ADJ-XY
ADJ-S
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
ADJ-Y-DF
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
STRD-POS
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
Adjustment of Reader shading position
To adjust the Scanner Unit (for front side) position in feed direction when reading the White Plate
on the left edge of the Copyboard Glass.
When replacing the Scanner Unit, execute RDSHDPOS and write the value of this item in the
service label.
When clearing the Reader-related RAM data, enter the value of service label.
As the value is incremented by 1, the reading position moves to the trailing edge side by 0.1 mm.
- When black lines/white lines appear
- When replacing the Scanner Unit (for front side)
- When clearing the Reader-related RAM data
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
After the setting value is changed, write the changed value in the service label.
-100 to 100
mm
0
COPIER> FUNCTION> INSTALL> RDSHDPOS
0.1
Adj start pstn: stream read, horz scan
To adjust the image reading start position in horizontal scanning direction at stream reading.
When replacing the Main Controller PCB/clearing the Reader-related RAM data, enter the value
of service label.
As the value is incremented by 1, the image position is moved to the rear side by 0.1 mm.
The setting is applied to only the image on the front side in the case of DADF (1-path model) or
the images on both the front and back sides in the case of DADF (reverse model).
When replacing the Main Controller PCB/clearing the Reader -related RAM data
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
After the setting value is changed, write the changed value in the service label.
-35 to 35
mm
0
0.1
Adj Scanner Unit pstn: stream, feed way
To adjust the position of the Scanner Unit on the Reader side in feed direction at stream reading.
When replacing the Main Controller PCB/clearing the Reader-related RAM data, enter the value
of service label.
The setting is applied to only the image on the front side in the case of DADF (1-path model) or
the images on both the front and back sides in the case of DADF (reverse model).
When replacing the Main Controller PCB/clearing the Reader -related RAM data
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
After the setting value is changed, write the changed value in the service label.
-50 to 50
mm
0
COPIER> FUNCTION> INSTALL> STRD-POS
0.1
801
9. Service Mode