E530-8001-02
Detection Description
Remedy
E530-8002-02
Detection Description
Remedy
a. Rear Alignment Motor error (Finisher-L) b. Error in the Front Alignment Motor (Finisher-
AB/A)
a. The Rear Alignment Plate HP Sensor was not turned OFF although 1 second had passed after
the Rear Alignment Motor operation started.
b. The front alignment plate does not come off the Front Alignment HP Sensor when the Front
Alignment Motor has been driven for 1 second.
[Related parts]
a. INNER FIN-L
- Harnesses and connectors from the Finisher Controller PCB to the Rear Alignment Plate HP
Sensor
- Harnesses and connectors from the Finisher Controller PCB to the Rear Alignment Motor
- Rear Alignment Plate HP Sensor (PS5)
- Rear Alignment Motor (M4)
- Finisher Controller PCB (PCB1)
b.STAPLE FIN-AB/BOOKLET FIN-AB, FOLD FIN-A
- Harnesses from the Front Alignment HP Sensor (PS115) to the Finisher Controller PCB
- Harnesses from the Front Alignment Motor (M107) to the Finisher Controller PCB
- Front Alignment HP Sensor (PS115)
- Front Alignment Motor (M107)
- Finisher Controller PCB (PCB101)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing
the Parts" in the Service Manual.
a. Rear Alignment Motor error (Finisher-L) b. Error in the Front Alignment Motor (Finisher-
AB/A)
a. The Rear Alignment Plate HP Sensor was not turned ON although 5 seconds had passed after
the Rear Alignment Motor operation started.
b. The Front Alignment HP Sensor does not detect the Front Alignment plate when the Front
Alignment Motor has been driven for 1 second.
[Related parts]
a. INNER FIN-L
- Harnesses and connectors from the Finisher Controller PCB to the Rear Alignment Plate HP
Sensor
- Harnesses and connectors from the Finisher Controller PCB to the Rear Alignment Motor
- Rear Alignment Plate HP Sensor (PS5)
- Rear Alignment Motor (M4)
- Finisher Controller PCB (PCB1)
b.STAPLE FIN-AB/BOOKLET FIN-AB, FOLD FIN-A
- Harnesses from the Front Alignment HP Sensor (PS115) to the Finisher Controller PCB
- Harnesses from the Front Alignment Motor (M107) to the Finisher Controller PCB
- Front Alignment HP Sensor (PS115)
- Front Alignment Motor (M107)
- Finisher Controller PCB (PCB1)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing