■ ITB Cleaning
Control description
After secondary transfer, the toner that remains on the ITB is removed before the next transfer.
1. The ITB Cleaning Blade scrapes toner on the ITB.
2. The scraped toner is fed to the Waste Toner Container by the ITB Cleaning Screw.
[3]
No.
Parts Name
1
ITB Cleaning Screw
2
ITB Cleaning Blade
3
Waste Toner Ejection Mouth
M2 ITB Motor
Related User Mode
Adjustment/Maintenance > Maintenance > Clean Inside Main Unit
Related Service Mode
Setting of the number of transparency to execute ITB cleaning
( Level 2 ) COPIER > Option > CLEANING > OHP-PTH
Setting band frequency change
( Level 2 ) COPIER > Option > IMG-TR > TR-BND2
( Level 2 ) COPIER > Option > IMG-TR > TRCLN1-P
( Level 2 ) COPIER > Option > IMG-TR > TRCLN2-P
( Level 2 ) COPIER > Option > IMG-TR > TR-BND3
( Level 2 ) COPIER > Option > IMG-TR > TRCLN3-P
( Level 2 ) COPIER > Option > IMG-TR > TRCLN4-P
( Level 2 ) COPIER > Option > IMG-TR > TR-BND2H
( Level 2 ) COPIER > Option > IMG-TR > TR-BND3H
( Level 2 ) COPIER > Option > IMG-TR > TRCLN1-H
( Level 2 ) COPIER > Option > IMG-TR > TRCLN2-H
( Level 2 ) COPIER > Option > IMG-TR > TRCLN3-H
( Level 2 ) COPIER > Option > IMG-TR > TRCLN4-H
( Level 2 ) COPIER > Option > IMG-TR > TRBND-SW
■ ITB Unit Detection (New/Old)
To detect a fuse substrate (UN74) of an ITB cleaning unit when power is turned on or when a right door is closed.
Judgment standard: When the voltage of the fuse board is 0 V (blown fuse condition), it is judged as an old product, and when
the voltage is a specified value, it is judged as a new product.
NOTE:
• When a new product is detected, the part counter/LIFE value is automatically cleared. (ITBCLN-U)
• After the new product is detected, a load voltage is applied to the fuse substrate (UN74), and the fuse is cut off.
M2
Residual toner collected in the ITB Cleaner Unit is fed.
Residual toner on the ITB is collected.
Ejection Mouth for toner collected on the ITB
The ITB Cleaning Screw is driven.
122
[2]
[1]
Roll