Main Controller PCB
Drum Driver PCB
Item
Alarm code name
Alarm code
Message
(Host machine operation)
Detection timing
Detected to (location)
Alarm log display
*1 : Whether to display/hide and the display timing can be specified in the following service modes (-1 to 365, -1: The alarm not
issued, the default value differs depending on the country.)
COPIER > OPTION > PM-DLV-D > PT-DR-Y
COPIER > OPTION > PM-DLV-D > PT-DR-M
COPIER > OPTION > PM-DLV-D > PT-DR-C
COPIER > OPTION > PM-DLV-D > PT-DRM
*2 : The life value and the remaining days of Drum Unit can be viewed in the following service mode.
COPIER > COUNTER > LIFE > PT-DR-Y
COPIER > COUNTER > LIFE > PT-DR-M
COPIER > COUNTER > LIFE > PT-DR-C
COPIER > COUNTER > LIFE > PT-DRM
*3 : After an advance notice alarm is sent, the next advance notice alarm will not be sent until the replacement completion alarm
is sent.
Service Mode
• Consumption level of Drum Unit (each color)
COPIER > COUNTER > LIFE > PT-DR-Y
COPIER > COUNTER > LIFE > PT-DR-M
COPIER > COUNTER > LIFE > PT-DR-C
COPIER > COUNTER > LIFE > PT-DRM
• Setting Drum Unit (each color) advance notice alarm notice timing
COPIER > OPTION > PM-DLV-D > PT-DR-Y
COPIER > OPTION > PM-DLV-D > PT-DR-M
COPIER > OPTION > PM-DLV-D > PT-DR-C
COPIER > OPTION > PM-DLV-D > PT-DRM
UN41
UN54
Information specific to the drum
Advance notice alarm
Drum Unit advance notice alarm *1
• 40-0070 : Y
• 40-0071 : M
• 40-0072 : C
• 40-0073 : K
-
When the consumption level of the Drum Unit reaches
the value set*1 for the Drum Unit (each color) advance
notice alarm notice timing *2.
Drum Unit Detection Sensor (New/Old)
ALARM-3 *3
Drum Unit Memory
Drum Unit replacement completion alarm
• 43-0070 : Y
• 43-0071 : M
• 43-0072 : C
• 43-0073 : Bk
-
When a new Drum Unit is detected.
ALARM-3
111
2. Technology
Replacement completion