8. Error/Jam/Alarm
E602-0015-00
SSD error
Detection Description
There was no file for downloading image coefficient.
Remedy
[Related parts]
- Harness between the Main Controller PCB and the SSD
- SSD
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check the related harness/cable and connector.
2. If the above-mentioned service mode cannot be executed due to an error, etc., enter safe mode.
Then format the SSD using SST or a USB flash drive. 3. Turn OFF and then ON the main power.
4. Reinstall the system software using SST or a USB flash drive.
5. Check/replace the related parts. [Reference 1]
For backup and restoration, refer to "Appendix> Backup Data List" in the System Service Manual.
[Reference 2]
Actions after Parts Replacement
1. Format the SSD.
Start the machine in safe mode, and format all partitions using SST or a USB flash drive.
2. Turn OFF and then ON the power of the host machine.
3. Restore the data backed up in [Actions before Parts Replacement].
4. Set/register the data again.
Set/register the data again by referring to the list that was printed before replacement.
5. When an encryption key/certificate/CA certificate has been generated or added by the user, ask
the user to execute regeneration.
6. Execute auto gradation adjustment.
- For Reader/ ADF model
Settings/Registration > Adjustment/Maintenance > Adjust Image Quality > Auto Adjust Gradation
> Full Adjust
- For Printer model
Settings/Registration > Adjustment/Maintenance > Adjust Image Quality > Auto Adjust Gradation
> Quick Adjust
562