E020-0124-05
Detection Description
Remedy
E020-0134-05
Detection Description
Remedy
ATR output error Y
The ATR Patch (Y) detected that the output value (SigD) was below the lower limit at initialization
of the Developing Assembly.
[Related parts]
- Laser Shutter (Y)
- Developing High Voltage PCB (UN58)(Unit of replacement: HIGH VOLTAGE POWER SUPPLY
UNIT)
- Drum Unit (Y)
- Charging High Voltage PCB (UN57)(Unit of replacement: HIGH VOLTAGE POWER SUPPLY
UNIT)
- Developing Assembly (Y)
- Laser Scanner Unit (YM)
- Main Controller (UN41)
- ITB Unit
- REGISTRATION SENSOR UNIT
- REG. DUPLEXING DRIVE ASSEMBLY
- DC Power Supply PCB (UN3) (Unit of replacement: POWER SUPPLY ASSEMBLY)
[Remedy]
a) When condensation is suspected
1. After checking that condensation has been completely eliminated, replace the Developing
Assembly (Y).
b) When there is no condensation, execute the following procedure while checking whether the
machine recovers from the error.
1. Clean the Exposure Window.
2. Clean the REGISTRATION SENSOR UNIT.
3. Check the installation status and opening and closing operations of the Laser Shutter (Y).
4. Execute the check/replace the related harness/cable, connector and parts
ATR output error Y
The ATR Patch (Y) detected that the output value (SigD) exceeded the upper limit at initialization
of the Developing Assembly.
[Related parts]
- Developing High Voltage PCB (UN58)(Unit of replacement: HIGH VOLTAGE POWER SUPPLY
UNIT)
- Drum Unit (Y)
- Charging High Voltage PCB (UN57)(Unit of replacement: HIGH VOLTAGE POWER SUPPLY
UNIT)
- Developing Assembly (Y)
- Laser Scanner Unit (YM)
- Main Controller (UN41)
- REGISTRATION SENSOR UNIT
- REG. DUPLEXING DRIVE ASSEMBLY
- DC Power Supply PCB (UN3)(Unit of replacement: POWER SUPPLY ASSEMBLY)
[Remedy]
Execute the check/replace the related harness/cable, connector and parts, while checking whether
the machine recovers from the error.
485
8. Error/Jam/Alarm