COPIER (Service mode for printer) > ADJUST (Adjustment mode) > CCD
DFCH-R2
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
DFCH-R10
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
DFCH-B2
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
Complex chart No.2 data (R) entry: back
To derive the front/back side linearity, enter the Red data on the back side of No.2 image in DADF
complex chart.
Enter the value of service label on the Reader.
The setting of this item is enabled only when the DADF (1-path model) is installed.
When replacing the Main Controller PCB/clearing the Reader -related RAM data
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When the Copyboard or DADF (reverse model) is installed, the setting of this item is disabled.
1 to 2550
2000
1
Complex chart No.10 data (R) entry: back
To derive the front/back side linearity, enter the Red data on the back side of No.10 image in DADF
complex chart.
Enter the value of service label on the Reader.
The setting of this item is enabled only when the DADF (1-path model) is installed.
When replacing the Main Controller PCB/clearing the Reader -related RAM data
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When the Copyboard or DADF (reverse model) is installed, the setting of this item is disabled.
0 to 2550
0
1
Complex chart No.2 data (B) entry: back
To derive the front/back side linearity, enter the Blue data on the back side of No.2 image in DADF
complex chart.
Enter the value of service label on the Reader.
The setting of this item is enabled only when the DADF (1-path model) is installed.
When replacing the Main Controller PCB/clearing the Reader -related RAM data
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When the Copyboard or DADF (reverse model) is installed, the setting of this item is disabled.
1 to 2550
2000
1
808