E009-0001-05
Detection Description
Remedy
E009-0002-05
Detection Description
Remedy
Fixing disengagement timeout error
The Pressure Release Sensor did not detect ON status within the specified period of time after the
start of fixing disengagement operation.
[Related parts]
- Harness connecting the Feed Driver PCB (UN1/J309) and Fixing Motor (M20/J2273)
- Harness connecting the Main Controller PCB (UN41/J74) and Feed Driver PCB (UN1/J307)
- Harness connecting the DC Power Supply PCB (UN3/J811) and Feed Driver PCB (UN1/J300)
- DC Power Supply PCB (UN3) (Unit of replacement: POWER SUPPLY ASSEMBLY)
- Main Controller PCB (UN41)
- Feed Driver PCB (UN1)
- Fixing Motor (M20)
- Fixing Unit
- Fixing Drive Unit
- Fixing Pressure Release Sensor (PS34)
[Remedy]
1. Turn OFF and then ON the main power.
2. Check that the Fixing Assembly is properly installed.
3. Check/replace the related harness/cable, connector and parts.
Fixing pressure error
The Pressure Release Sensor did not detect OFF status within the specified period of time after
the start of fixing disengagement operation.
[Related parts]
- Harness connecting the Feed Driver PCB (UN1/J309) and Fixing Motor (M20/J2273)
- Harness connecting the Main Controller PCB (UN41/J74) and Feed Driver PCB (UN1/J307)
- Harness connecting the DC Power Supply PCB (UN3/J811) and Feed Driver PCB (UN1/J300)
- DC Power Supply PCB (UN3) (Unit of replacement: POWER SUPPLY ASSEMBLY)
- Main Controller PCB (UN41)
- Feed Driver PCB (UN1)
- Fixing Motor (M20)
- Fixing Unit
- Fixing Drive Unit
- Fixing Pressure Release Sensor (PS34)
[Remedy]
1. Turn OFF and then ON the main power.
2. Check that the Fixing Assembly is properly installed.
3. Check/replace the related harness/cable, connector and parts.
477