E001-0007-05
Detection Description
Remedy
E002-0001-05
Detection Description
Remedy
Thermistor overheating error by hardware detection
At least one Thermistor detected a high temperature error by hardware detection.
Main Thermistor/Sub Thermistor F/Sub Thermistor R/Film Thermistor C
[Related parts]
- Harness connecting the Drum Driver PCB (UN54/J205), Drawer Unit (J5012), and the Fixing Film
Unit
- DC Power Supply PCB (UN3)(Unit of replacement: POWER SUPPLY ASSEMBLY)
- Drum Driver PCB (UN54)
- Main Controller PCB (UN41)
- Feed Driver PCB (UN1)
- Fixing Unit
- SIDE END COOLING FAN ASS'Y
- Fixing Drive Unit
[Remedy]
- Check the detected temperature of all Fixing Thermistors.
a. If it is the upper limit temperature or lower, go through the following to clear the error: COPIER
> FUNCTION > CLEAR > ERR. Then, turn OFF and then ON the main power.
b. If it exceeds the upper limit temperature, check/replace the related harness/cable, connector
and parts.
[CAUTION]
Do not turn ON the power before replacing the Fixing Film Unit.
After performing the remedy work, go through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
Main Thermistor temperature increase error
After the Fixing Heater was turned ON, the Main Thermistor detected no temperature increase.
[Related parts]
- Harness connecting the Drum Driver PCB (UN54/J205), Drawer Unit (J5012), and the Fixing Film
Unit
- Harness connecting the AC Driver PCB (UN2/J604), Drawer Unit (J5012), and Fixing Film Unit
- DC Power Supply PCB (UN3)(Unit of replacement: POWER SUPPLY ASSEMBLY)
- Drum Driver PCB (UN54)
- AC Driver PCB (UN2)
- Main Controller PCB (UN41)
- Feed Driver PCB (UN1)
- SIDE END COOLING FAN ASS'Y
- Fixing Unit
- Fixing Drive Assembly
[Remedy]
Perform the following in the order while checking whether the error is cleared.
1. Go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR. Then, turn
OFF and then ON the main power.
2. Check/replace the related harness/cable, connector and parts.
After performing the remedy work, go through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
468