COPIER (Service mode for printer) > DISPLAY (State display mode) > ANALOG
FIX-E2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
TEMP2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
HUM2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
FIX-E3
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
FIX-F
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
1
Dspl Fixing Heater front edg temperature
To display the front edge temperature of the Fixing Heater detected by the Sub Thermistor F.
When checking the edge temperature of the Fixing Heater
N/A (Display only)
0 to 300
deg C
20 - 250
1
1
Display of inside temperature
To display the temperature inside the machine measured by Environment Sensor 1.
When checking the temperature inside the machine
N/A (Display only)
0 to 100
deg C
20 - 27
1
1
Display of inside humidity
To display the humidity inside the machine measured by Environment Sensor 1.
When checking the humidity inside the machine
N/A (Display only)
0 to 100
%
30 - 70
1
1
Dspl Fixing Heater rear edge temperature
To display the rear edge temperature of the Fixing Heater detected by the Sub Thermistor R.
When checking the edge temperature of the Fixing Heater
N/A (Display only)
0 to 300
deg C
20 - 250
1
1
Dspl Fixing Film front edge temperature
To display the front edge temperature of the Fixing Film detected by the Film Thermistor F.
When checking the edge temperature of the Fixing Film
N/A (Display only)
0 to 300
deg C
774