Error Code
Error Code Details
E001-0001-05
Detection Description
Remedy
E001-0002-05
Detection Description
Remedy
Main Thermistor high temperature detection error
The Main Thermistor detected a high temperature error.
[Related parts]
- Harness connecting the Drum Driver PCB (UN54/J205), Drawer Unit (J5012), and the Fixing Film
Unit
- DC Power Supply PCB (UN3)(Unit of replacement: POWER SUPPLY ASSEMBLY)
- Drum Driver PCB (UN54)
- Main Controller PCB (UN41)
- Feed Driver PCB (UN1)
- Fixing Unit
- SIDE END COOLING FAN ASS'Y
- Fixing Drive Unit
[Remedy]
- Check COPIER > DISPLAY > ANALOG > FIX-E.
a. In the case of below 283 deg C, go through the following to clear the error: COPIER > FUNCTION
> CLEAR > ERR. Then, turn OFF and then ON the main power.
b. In the case of 283 deg C or higher, check/replace the related harness/cable, connector and
parts.
[Caution]
When replacing the Fixing Film Unit, do not turn ON the power before replacement.
After performing the remedy work, go through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
Sub Thermistor F high temperature detection error
The Sub Thermistor F detected a high temperature error.
[Related parts]
- Harness connecting the Drum Driver PCB (UN54/J205), Drawer Unit (J5012), and the Fixing Film
Unit
- DC Power Supply PCB (UN3)(Unit of replacement: POWER SUPPLY ASSEMBLY)
- Drum Driver PCB (UN54)
- Main Controller PCB (UN41)
- Feed Driver PCB (UN1)
- Fixing Unit
- SIDE END COOLING FAN ASS'Y
- Fixing Drive Unit
[Remedy]
- Check COPIER > DISPLAY > ANALOG > FIX-E2.
a. In the case of below 295 deg C, go through the following to clear the error: COPIER > FUNCTION
> CLEAR > ERR. Then, turn OFF and then ON the main power.
b. In the case of 295 deg C or higher, check/replace the related harness/cable, connector and
parts.
[Caution]
When replacing the Fixing Film Unit, do not turn ON the power before replacement.
After performing the remedy work, go through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
465