Code
E002
0004
After the Fixing Heater was turned ON, the Sub Thermistor F detected error in temperature in-
crease.
0005
After the Fixing Heater was turned ON, the Sub Thermistor R detected error in temperature in-
crease.
0006
After the Fixing Heater was turned ON, the Film Thermistor C detected error in temperature in-
crease.
0007
After the Fixing Heater was turned ON, the Film Thermistor F detected error in temperature in-
crease.
0008
After the Fixing Heater was turned ON, the Film Thermistor R detected error in temperature in-
crease.
0009
The Film Thermistor C detected error in temperature increase.
0010
The Film Thermistor F detected error in temperature increase.
0011
The Film Thermistor R detected error in temperature increase.
E003
Detection of low temperature
0001
The Main Thermistor detected an abnormally low temperature during print control.
0002
The Sub Thermistor F detected an abnormally low temperature during print control.
0003
The Sub Thermistor R detected an abnormally low temperature during print control.
0004
The Film Thermistor C detected an abnormally low temperature during print control.
0005
The Film Thermistor F detected an abnormally low temperature during print control.
0006
The Film Thermistor R detected an abnormally low temperature during print control.
0007
An error in temperature difference between the Film Thermistor F and R was detected during print
control.
E004
Detection of error in the Fixing Heater drive circuit
0000
Open circuit of the Thermistor or connector disconnection was detected.
0001
Welding of the fixing relay on the AC Driver PCB was detected.
0002
When the voltage models of the host machine and Fixing Assembly Memory are different
E009
Detection of error in fixing engagement/disengagement
0001
The Pressure Release Sensor did not detect ON status within 5 sec after the start of fixing disen-
gagement operation.
0002
The Pressure Release Sensor did not detect OFF status within 5 sec after the start of fixing dis-
engagement operation.
E014
Fixing Motor error
0001
Lock error of the Fixing Motor was detected.
0002
Detecting the unlocking of the fixing motor
E808
Detection of error in fixing drive circuit/power supply
0000
Zero cross signal was not detected after fixing relay was ON.
*1: After performing the remedy work, the error can be cleared in the following service mode
• COPIER > FUNCTION > CLEAR > ERR
Description
157
2. Technology
Clearing of
error
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Required*1
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required