hit counter script

Dell EMC VxFlex Ready Node User Manual page 304

Hide thumbs Also See for EMC VxFlex Ready Node:
Table of Contents

Advertisement

SNMP Trap Support
Alert Message in
Alert Message in
VxFlex OS GUI
REST
will be relocated to
another device.
Device malfunction
DEVICE_ERROR_NOTIC
has been detected.
E
Minor failures have
DEVICE_ERROR_INFO
been detected in
device performance.
The SDC is either
SDC_DISCONNECTED
down or unreachable
over the network
No more SDCs can
SDC_MAX_COUNT
be defined on this
system; the
maximum has been
reached
SSD lifespan is over
PHYSICAL_DRIVE_END
endurance threshold
URANCE_USED_ABOV
E_THRESHOLD
The Physical Disk
PHYSICAL_DRIVE_INVA
temperature has
LID_TEMPERATURE
exceeded the
configured threshold
The Physical Drive's
PHYSICAL_DRIVE_INVA
cache is not disabled
LID_PD_CACHE_POLIC
Y
Device was
DEVICE_SHOULD_USE
requested to use as
_AS_DAS_CACHE_BUT
DAS Cache but it is
_IT_IS_NOT
not
The Logical Disk
LOGICAL_DISK_INVALI
read policy is not set
D_READ_AHEAD_POLI
to "Read-Ahead"
CY
Dell EMC VxFlex Ready Node AMS User Guide
304
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
SDS.Device.De
vice_ErrorNotic
e
SDS.Device.De
vice_ErrorInfo
SDC.SDC.SDC
_DISCONNECT
ED
SDC.SDC.SDC
_Max_Count
Storage_Contr
oller.Physical_D
rive.Endurance
_Used_Above_
Threshold
Storage_Contr
oller.Physical_D
rive.INVALID_T
EMPERATURE
Storage_Contr
oller.Physical_D
rive.INVALID_P
D_CACHE_POL
ICY
Storage_Contr
oller.Physical_D
rive.Device_Sh
ould_Use_As_D
as_Cache_But_
It_Is_Not
Storage_Contr
oller.Logical_Di
sk.INVALID_RE
AD_AHEAD_P
OLICY
Alert Code
Severity
(for ESRS)
SIO03.02.000
2 (Warning)
0007
SIO03.02.000
2 (Warning)
0008
SIO04.01.000
3 (Error)
0001
SIO04.01.000
3 (Error)
0002
SIO06.01.000
5 (Critical)
0004
SIO06.01.000
5 (Critical) 3
0005
(Error)
SIO06.01.000
3 (Error)
0006
SIO06.01.000
3 (Error)
0007
SIO06.02.00
3 (Error)
00001
Recommended Action
Check the device, and if
necessary, replace it
Check the device, and if
necessary, replace it
Verify that the SDC service
is up and running and that
the network is properly
configured and connected.
The maximum number of
SDCs in the system has
been reached (1024^2).
Replace the SSD device.
Ensure that the server and
its environment are
properly cooled. Ensure
that the internal chassis
fans are working, and that
there is adequate airflow.
Disable the Physical Drive
physical cache. Note: This
may cause DI issues in
power cycle scenarios.
Access the storage
controller and change the
Logical Disk's read policy to
"Read Ahead".

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents