SNMP Trap Support
Alert Message in
Alert Message in
VxFlex OS GUI
REST
RFcache pool state
XTREMCACHE_INVALI
is "Not Started"
D_STATE
Host certificate is
HOST_CERTIFICATE_A
about to expire
BOUT_TO_EXPIRE
CMOS battery state
NODE_INVALID_CMOS
is invalid
_BATTERY
The node is not
NODE_NOT_MANAGED
being managed by
_BY_AMS
the current AMS.
Failed to connect to
NODE_FAILED_TO_CO
the SVM due to
NNECT_TO_SVM_AUT
authentication
H_FAILED
failure
Failed to connect to
NODE_FAILED_TO_CO
the host. The SSH
NNECT_TO_HOST_SS
key has been
H_KEY_MISMATCH
changed, and is not
trusted by the AMS.
Failed to connect to
NODE_FAILED_TO_CO
the SVM. The SSH
NNECT_TO_SVM_SSH
key has been
_KEY_MISMATCH
changed, and is not
trusted by the AMS.
Failed to connect to
NODE_FAILED_TO_CO
the host because
NNECT_TO_ESX_CERT
the certificate is not
IFICATE_NOT_TRUSTE
trusted
D
Failed to connect to
NODE_FAILED_TO_CO
the host due to
NNECT_TO_HOST_AU
authentication
TH_FAILED
failure
The MDM has a self-
AMS_MDM_HAS_SELF
signed certificate
_SIGNED_CERTIFICATE
that was not
replaced by the
Dell EMC VxFlex Ready Node AMS User Guide
310
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
Node.Node.XT
REMCACHE_IN
VALID_STATE
Node.Node.HO
ST_CERTIFICA
TE_ABOUT_TO
_EXPIRE
Node.Node.Inva
lid_Cmos_Batte
ry
Node.Node.Nod
e_Not_Manage
d_By_Ams
Node.Node.Nod
e_Failed_To_C
onnect_To_Sv
m_Auth_Failed
Node.Node.Nod
e_Failed_To_C
onnect_To_Hos
t_Ssh_Key_Mis
match
Node.Node.Nod
e_Failed_To_C
onnect_To_Sv
m_Ssh_Key_Mi
smatch
Node.Node.Nod
e_Failed_To_C
onnect_To_Esx
_Certificate_N
ot_Trusted
Node.Node.Nod
e_Failed_To_C
onnect_To_Hos
t_Auth_Failed
Node.Node.Am
s_Mdm_Has_S
elf_signed_cert
ificate
Alert Code
Severity
(for ESRS)
SIO07.05.000
3 (Error)
0010
SIO07.05.000
3 (Error)
0014
SIO07.05.000
3 (Error)
0015
SIO07.05.000
5 (Critical)
0016
SIO07.05.000
5 (Critical)
0017
SIO07.05.000
5 (Critical)
0018
SIO07.05.000
5 (Critical)
0019
SIO07.05.000
5 (Critical)
0020
SIO07.05.000
5 (Critical)
0021
SIO07.05.000
5 (Critical)
0022
Recommended Action
Check the Read Flash
Cache pool state. The
cache device might be
misconfigured. In this case,
remove the cache device
from the cache pool and
add it back again.
Renew the AMS certificate
and then run "renew
certificate" process
Check the node's CMOS
battery. It may need to be
replaced.
Verify that the node is not
being managed by a
different AMS.
Change the SVM's root
password to be the one set
by the AMS
This is a security issue.
Remove the node, and add
the node again to the AMS.
This is a security issue.
Remove the node, and add
the node again to the AMS.
This is a security issue.
Remove the node, and add
the node again to the AMS.
Change the host's root
password to be the one set
by the AMS
Disable AMS secure
connection, and enable it
again in order to
automatically sign the MDM