SNMP Trap Support
Alert Message in
Alert Message in
VxFlex OS GUI
REST
RAM voltage
RAM_INVALID_VR_TE
regulator's
MPERATURE
temperature is not
within threshold
RAM voltage
RAM_INVALID_VR_VOL
regulator's voltage is
TAGE
not within threshold
The node
NODE_INVALID_TEMPE
temperature has
RATURE
exceeded the
configured threshold
The voltage values
NODE_INVALID_VOLTA
on the node are not
GE
within the
configured threshold
Unable to connect
NODE_FAILED_TO_CO
to monitoring agent
NNECT_TO_BMC
(BMC)
SDC is not installed
NODE_WITH_NO_SDC
on this node
Unable to connect
NODE_FAILED_TO_CO
to monitoring agent
NNECT_TO_SVM
(SVM)
Dell EMC VxFlex Ready Node AMS User Guide
308
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
Node.Ram.INV
ALID_VR_TEM
PERATURE
Node.Ram.INV
ALID_VR_VOLT
AGE
Node.Node.INV
ALID_TEMPER
ATURE
Node.Node.INV
ALID_VOLTAG
E
Node.Node.FAI
LED_TO_CON
NECT_TO_BM
C
Node.Node.NO
DE_WITH_NO_
SDC
Node.Node.FAI
LED_TO_CON
NECT_TO_SV
M
Alert Code
Severity
(for ESRS)
SIO07.04.000
5 (Critical) 3
0002
(Error)
SIO07.04.000
5 (Critical) 3
0003
(Error)
SIO07.05.000
5 (Critical) 3
0001
(Error)
SIO07.05.000
5 (Critical) 3
0002
(Error)
SIO07.05.000
5 (Critical)
0004
SIO07.05.000
3 (Error)
0005
SIO07.05.000
5 (Critical)
0006
Recommended Action
Ensure that the server and
its environment are
properly cooled and that all
the chassis fans are
functional.
Ensure that the server and
its environment are
properly cooled and that all
the chassis fans are
functional. If the system
still issues an alert, the
DIMM may be faulty, and
may have to be replaced.
Ensure that the server and
its environment are
properly cooled and that all
the chassis fans are
functional.
1. Verify that the power
supply is functioning
correctly, and then try to
replace a port in the Power
Distribution Unit or check
with external power. 2.
Replace the power cable. 3.
Replace the Power Supply
Module.
The BMC IP address or
User credentials do not
respond to AMS queries.
Verify network connectivity
from the AMS to the BMC
IP address, and check that
the BMC admin user and
password have not been
tampered with. Contact
customer support for
assistance if the problem
persists.
Consider installing an SDC
on this node, so that it can
use VxFlex OS volumes
The SVM IP address or
User credentials do not
respond to AMS queries.
Check the SVM state in