Alert Message in
Alert Message in
VxFlex OS GUI
REST
The physical CPU
SOCKET_DISABLED
socket is not
enabled
Not all CPU cores
SOCKET_NOT_ALL_CO
are enabled
RES_ENABLED
CPU is not operating
SOCKET_SPEED_IS_N
at full speed
OT_MAX_SPEED
CPU temperature is
CPU_SOCKET_INVALID
not within threshold
_TEMPERATURE
The CPU Voltage
CPU_SOCKET_INVALID
Regulator's
_VR_TEMPERATURE
temperature is
higher than the
configured threshold
The CPU Voltage
CPU_SOCKET_INVALID
Regulator's voltage
_VR_VOLTAGE
is not within the
configured threshold
CPU has invalid
CPU_SOCKET_INVALID
voltage state state
_VOLTAGE
RAM temperature is
RAM_INVALID_TEMPE
not within threshold
RATURE
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
Node.Cpu_Soc
ket.Disabled
Node.Cpu_Soc
ket.NOT_ALL_
CORES_ENABL
ED
Node.Cpu_Soc
ket.SPEED_IS_
NOT_MAX_SP
EED
Node.Cpu_Soc
ket.INVALID_T
EMPERATURE
Node.Cpu_Soc
ket.INVALID_V
R_TEMPERAT
URE
Node.Cpu_Soc
ket.INVALID_V
R_VOLTAGE
Node.Cpu_Soc
ket.Invalid_Volt
age
Node.Ram.Inval
id_Temperature
Alert Code
Severity
(for ESRS)
SIO07.03.000
3 (Error)
0001
SIO07.03.000
3 (Error)
0002
SIO07.03.000
3 (Error)
0003
SIO07.03.000
5 (Critical) 3
0004
(Error)
SIO07.03.000
5 (Critical) 3
0005
(Error)
SIO07.03.000
5 (Critical) 3
0006
(Error)
SIO07.03.000
5 (Critical)
0007
SIO07.04.000
5 (Critical) 3
0001
(Error)
Dell EMC VxFlex Ready Node AMS User Guide
SNMP Trap Support
Recommended Action
Enable the CPU socket in
the server BIOS.
Change the physical CPU
core configuration in the
server BIOS.
Set the CPU clock speed in
the server's BIOS to its
maximum speed.
The server's CPU
temperature has exceeded
the configured threshold.
Make sure that the server is
properly cooled and that
the CPU and internal
chassis fans are active.
Make sure that the server is
properly cooled and that
the CPU and internal
chassis fans are active.
1. Verify that the power
supply is functioning
correctly. 2. Try to replace
a port in the Power
Distribution Unit, or supply
an external power source to
check it. 3. Replace the
power cable. 4. Replace the
Power Supply Unit module.
Check the chassis power
supply
The temperature of one or
more Server RAM modules
exceeds the configured
threshold. Ensure that the
server and its environment
are properly cooled and
that all the chassis fans are
functional.
307