hit counter script

Dell EMC VxFlex Ready Node User Manual page 318

Hide thumbs Also See for EMC VxFlex Ready Node:
Table of Contents

Advertisement

SNMP Trap Support
Alert Message in
Alert Message in
VxFlex OS GUI
REST
Node serial number
NODE_SERIAL_NU
has changed
MBER_CHANGE
RFcache pool state
XTREMCACHE_INV
is "Not Started"
ALID_STATE
Host certificate is
HOST_CERTIFICAT
about to expire
E_ABOUT_TO_EXP
IRE
CMOS battery state
NODE_INVALID_C
is invalid
MOS_BATTERY
The node is not
NODE_NOT_MANA
being managed by
GED_BY_AMS
the current AMS.
Failed to connect to
NODE_FAILED_TO
the SVM due to
_CONNECT_TO_S
authentication
VM_AUTH_FAILED
failure
Failed to connect to
NODE_FAILED_TO
the host. The SSH
_CONNECT_TO_H
key has been
OST_SSH_KEY_MI
changed, and is not
SMATCH
trusted by the AMS.
Dell EMC VxFlex Ready Node AMS User Guide
318
Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
SNMP Trap
Node.Node.SERIAL
_NUMBER_CHANG
E
Node.Node.XTREM
CACHE_INVALID_S
TATE
Node.Node.HOST_
CERTIFICATE_ABO
UT_TO_EXPIRE
Node.Node.Invalid_
Cmos_Battery
Node.Node.Node_N
ot_Managed_By_A
ms
Node.Node.Node_F
ailed_To_Connect_
To_Svm_Auth_Faile
d
Node.Node.Node_F
ailed_To_Connect_
To_Host_Ssh_Key_
Mismatch
Alert Code
Severity
(for ESRS)
SIO07.05.000
3 (Error)
0009
SIO07.05.000
3 (Error)
0010
SIO07.05.000
3 (Error)
0014
SIO07.05.000
3 (Error)
0015
SIO07.05.000
5 (Critical) Verify that the node is not
0016
SIO07.05.000
5 (Critical) Change the SVM's root
0017
SIO07.05.000
5 (Critical) This is a security issue.
0018
Recommended Action
The S/N of the Motherboard
does not match the IP
address of the ESX. Either
the SATADOM was moved to
a new server or the
motherboard was replaced. It
is also possible that a new
server that has the same IP
addresses and the same user
and password, but was not
installed using the AMS flow,
exists in the network. EMC
does not support such field
replacement cases. Such
cases should be solved by
replacing nodes using EMC-
recommended procedures.
For more information,
contact Customer Support.
Check the Read Flash Cache
pool state. The cache device
might be misconfigured. In
this case, remove the cache
device from the cache pool
and add it back again.
Renew the AMS certificate
and then run "renew
certificate" process
Check the node's CMOS
battery. It may need to be
replaced.
being managed by a different
AMS.
password to be the one set
by the AMS
Remove the node, and add
the node again to the AMS.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents