hit counter script

Dell EMC VxFlex Ready Node User Manual page 306

Hide thumbs Also See for EMC VxFlex Ready Node:
Table of Contents

Advertisement

SNMP Trap Support
Alert Message in
Alert Message in
VxFlex OS GUI
REST
There is no backup
BATTERY_NOT_PRESE
battery installed in
NT
the storage
controller
The storage
BATTERY_INVALID_PA
controller contains
CK_ENERGY
an incompatible
battery pack
RAID controller's
BATTERY_INVALID_VO
battery has invalid
LTAGE
voltage state
Hypervisor boot
BOOT_DRIVE_INVALID_
drive state is not OK
STATE
The storage
STORAGE_CONTROLL
controller is not
ER_INVALID_STATE
operating optimally
The storage
STORAGE_CONTROLL
controller
ER_INVALID_TEMPERA
temperature has
TURE
exceeded the
configured threshold
CacheCade license
STORAGE_CONTROLL
is not installed
ER_CACHECADE_NOT_
LICENSED
Some of the disk
STORAGE_CONTROLL
slots in the storage
ER_NOT_ALL_SLOTS_
controller are empty
FULL
Unable to query
NODE_FAILED_TO_QU
RAID controller due
ERY_RAID_CONTROLL
to insufficient
ER_INVALID_PERMISSI
permissions
ONS
Dell EMC VxFlex Ready Node AMS User Guide
306
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
Storage_Contr
oller.Battery.N
OT_PRESENT
Storage_Contr
oller.Battery.Inv
alid_Pack_Ener
gy
Storage_Contr
oller.Battery.Inv
alid_Voltage
Node.Boot_Driv
e.Invalid_State
Node.Storage_
Controller.Invali
d_State
Node.Storage_
Controller.Invali
d_Temperature
Node.Storage_
Controller.Cach
ecade_Not_Lic
ensed
Node.Storage_
Controller.Not_
All_Slots_Full
Node.Storage_
Controller.NOD
E_FAILED_TO_
QUERY_RAID_
CONTROLLER
_INVALID_PER
MISSIONS
Alert Code
Severity
(for ESRS)
SIO06.03.00
5 (Critical)
00004
SIO06.03.00
3 (Error)
00005
SIO06.03.00
3 (Error)
00006
SIO07.01.000
3 (Error)
0001
SIO07.02.000
5 (Critical)
0001
SIO07.02.000
5 (Critical) 3
0002
(Error)
SIO07.02.000
3 (Error)
0003
SIO07.02.000
3 (Error)
0004
SIO07.02.000
5 (Critical)
0005
Recommended Action
Install a backup battery in
the storage controller.
Replace the storage
controller battery with one
that is compatible with your
controller's model.
Check the RAID controller's
battery. It may need to be
replaced.
The drive on which the
ESXi hypervisor is installed
has reported an error.
Replace the drive and
reinstall the ESXi on the
new drive.
The storage controller may
be faulty, and should be
replaced.
Ensure that the server and
its environment are
properly cooled and that all
the chassis fans are
functional.
Install a CacheCade license
on the storage controller.
Add more disks if needed. If
a disk was removed during a
FRU (Field Replacement
Unit) operation, insert the
new disk into the chassis.
Verify that the user name
and password of the
Storage VM match the user
name and password
configured in the AMS
(System Settings menu >
System Settings > Security
option). Resolve the
differences and try again.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents