SNMP Trap Support
Alert Message in
Alert Message in
VxFlex OS GUI
REST
higher than the
configured
threshold
The CPU Voltage
CPU_SOCKET_INV
Regulator's voltage
ALID_VR_VOLTAGE
is not within the
configured
threshold
CPU has invalid
CPU_SOCKET_INV
voltage state state
ALID_VOLTAGE
RAM temperature is
RAM_INVALID_TE
not within threshold
MPERATURE
RAM voltage
RAM_INVALID_VR_
regulator's
TEMPERATURE
temperature is not
within threshold
RAM voltage
RAM_INVALID_VR_
regulator's voltage
VOLTAGE
is not within
threshold
The node
NODE_INVALID_TE
temperature has
MPERATURE
exceeded the
configured
threshold
The voltage values
NODE_INVALID_VO
on the node are not
LTAGE
within the
configured
threshold
Dell EMC VxFlex Ready Node AMS User Guide
316
Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
SNMP Trap
Node.Cpu_Socket.I
NVALID_VR_VOLTA
GE
Node.Cpu_Socket.I
nvalid_Voltage
Node.Ram.Invalid_T
emperature
Node.Ram.INVALID
_VR_TEMPERATUR
E
Node.Ram.INVALID
_VR_VOLTAGE
Node.Node.INVALID
_TEMPERATURE
Node.Node.INVALID
_VOLTAGE
Alert Code
Severity
(for ESRS)
SIO07.03.000
5 (Critical)
0006
3 (Error)
SIO07.03.000
5 (Critical) Check the chassis power
0007
SIO07.04.000
5 (Critical)
0001
3 (Error)
SIO07.04.000
5 (Critical)
0002
3 (Error)
SIO07.04.000
5 (Critical)
0003
3 (Error)
SIO07.05.000
5 (Critical)
0001
3 (Error)
SIO07.05.000
5 (Critical)
0002
3 (Error)
Recommended Action
CPU and internal chassis fans
are active.
1. Verify that the power
supply is functioning
correctly. 2. Try to replace a
port in the Power Distribution
Unit, or supply an external
power source to check it. 3.
Replace the power cable. 4.
Replace the Power Supply
Unit module.
supply
The temperature of one or
more Server RAM modules
exceeds the configured
threshold. Ensure that the
server and its environment
are properly cooled and that
all the chassis fans are
functional.
Ensure that the server and its
environment are properly
cooled and that all the
chassis fans are functional.
Ensure that the server and its
environment are properly
cooled and that all the
chassis fans are functional. If
the system still issues an
alert, the DIMM may be
faulty, and may have to be
replaced.
Ensure that the server and its
environment are properly
cooled and that all the
chassis fans are functional.
1. Verify that the power
supply is functioning
correctly, and then try to
replace a port in the Power
Distribution Unit or check
with external power. 2.

Hide quick links: