Alert Message in
Alert Message in
VxFlex OS GUI
REST
The storage
STORAGE_CONTR
controller is not
OLLER_INVALID_S
operating optimally
TATE
The storage
STORAGE_CONTR
controller
OLLER_INVALID_T
temperature has
EMPERATURE
exceeded the
configured
threshold
CacheCade license
STORAGE_CONTR
is not installed
OLLER_CACHECAD
E_NOT_LICENSED
Some of the disk
STORAGE_CONTR
slots in the storage
OLLER_NOT_ALL_
controller are empty
SLOTS_FULL
Unable to query
NODE_FAILED_TO
RAID controller due
_QUERY_RAID_CO
to insufficient
NTROLLER_INVALI
permissions
D_PERMISSIONS
The physical CPU
SOCKET_DISABLE
socket is not
D
enabled
Not all CPU cores
SOCKET_NOT_ALL
are enabled
_CORES_ENABLED
CPU is not
SOCKET_SPEED_I
operating at full
S_NOT_MAX_SPE
speed
ED
CPU temperature is
CPU_SOCKET_INV
not within threshold
ALID_TEMPERATU
RE
The CPU Voltage
CPU_SOCKET_INV
Regulator's
ALID_VR_TEMPER
temperature is
ATURE
Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
SNMP Trap
Node.Storage_Cont
roller.Invalid_State
Node.Storage_Cont
roller.Invalid_Tempe
rature
Node.Storage_Cont
roller.Cachecade_N
ot_Licensed
Node.Storage_Cont
roller.Not_All_Slots
_Full
Node.Storage_Cont
roller.NODE_FAILE
D_TO_QUERY_RAI
D_CONTROLLER_I
NVALID_PERMISSI
ONS
Node.Cpu_Socket.D
isabled
Node.Cpu_Socket.N
OT_ALL_CORES_E
NABLED
Node.Cpu_Socket.S
PEED_IS_NOT_MA
X_SPEED
Node.Cpu_Socket.I
NVALID_TEMPERA
TURE
Node.Cpu_Socket.I
NVALID_VR_TEMP
ERATURE
Alert Code
Severity
(for ESRS)
SIO07.02.000
5 (Critical) The storage controller may
0001
SIO07.02.000
5 (Critical)
0002
3 (Error)
SIO07.02.000
3 (Error)
0003
SIO07.02.000
3 (Error)
0004
SIO07.02.000
5 (Critical) Verify that the user name and
0005
SIO07.03.000
3 (Error)
0001
SIO07.03.000
3 (Error)
0002
SIO07.03.000
3 (Error)
0003
SIO07.03.000
5 (Critical)
0004
3 (Error)
SIO07.03.000
5 (Critical)
0005
3 (Error)
Dell EMC VxFlex Ready Node AMS User Guide
SNMP Trap Support
Recommended Action
be faulty, and should be
replaced.
Ensure that the server and its
environment are properly
cooled and that all the
chassis fans are functional.
Install a CacheCade license
on the storage controller.
Add more disks if needed. If a
disk was removed during a
FRU (Field Replacement
Unit) operation, insert the
new disk into the chassis.
password of the Storage VM
match the user name and
password configured in the
AMS (System Settings menu
> System Settings > Security
option). Resolve the
differences and try again.
Enable the CPU socket in the
server BIOS.
Change the physical CPU
core configuration in the
server BIOS.
Set the CPU clock speed in
the server's BIOS to its
maximum speed.
The server's CPU
temperature has exceeded
the configured threshold.
Make sure that the server is
properly cooled and that the
CPU and internal chassis fans
are active.
Make sure that the server is
properly cooled and that the
315