hit counter script

Dell EMC VxFlex Ready Node User Manual page 311

Hide thumbs Also See for EMC VxFlex Ready Node:
Table of Contents

Advertisement

Alert Message in
Alert Message in
VxFlex OS GUI
REST
AMS. Connection to
the MDM is not
authenticated by the
AMS.
CPU cache is not
SOCKET_CACHE_DISA
enabled
BLED
CPU cache size is
SOCKET_CACHE_SIZE
not optimal
_NOT_MAX_SIZE
Unable to connect
ESRS_CONNECTIVITY_
to ESRS Gateway
ERROR
The system is not
ESRS_NOT_REGISTER
registered with an
ED
ESRS gateway
ESRS number of
ESRS_REACHED_CAPA
messages received
CITY_LIMIT
has been reached.
No more messages
will be sent in the
next 8 hours
SDC is disconnected
ONE_SDC_DISCONNEC
from SDS
TED_FROM_ONE_SDS
SDC is disconnected
ONE_SDC_DISCONNEC
from the SDS IP
TED_FROM_ONE_SDS
address
_IP
An SDC is
ONE_SDC_DISCONNEC
disconnected from
TED_FROM_ALL_SDS
all SDSs
All SDCs are
ALL_SDC_DISCONNEC
disconnected from
TED_FROM_ONE_SDS
the SDS
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
Cpu_Socket.So
cket_Cache.Dis
abled
Cpu_Socket.So
cket_Cache.SIZ
E_NOT_MAX_
SIZE
Esrs.Esrs.CON
NECTIVITY_ER
ROR
Esrs.Esrs.NOT_
REGISTERED
Esrs.Esrs.REAC
HED_CAPACIT
Y_LIMIT
System.SDC.O
ne_Sdc_Discon
nected_From_
One_Sds
System.SDC.O
ne_Sdc_Discon
nected_From_
One_Sds_Ip
System.SDC.O
ne_Sdc_Discon
nected_From_
All_Sds
System.SDC.All
_Sdc_Disconne
Alert Code
Severity
(for ESRS)
SIO08.01.000
3 (Error)
0001
SIO08.01.000
3 (Error)
0002
SIO10.01.000
5 (Critical)
0001
SIO10.01.000
2 (Warning)
0004
SIO10.01.000
5 (Critical)
0005
SIO01.07.000
5 (Critical)
0001
SIO01.07.000
2 (Warning)
0002
SIO01.07.000
5 (Critical)
0003
SIO01.07.000
5 (Critical)
0004
Dell EMC VxFlex Ready Node AMS User Guide
SNMP Trap Support
Recommended Action
certificate. If the previous
solution does not work,
remove and add the the
MDM again in secure mode.
Enable the CPU cache in
the server BIOS.
Check the CPU cache in
the server BIOS, and set it
to maximum size.
Check the network's
connectivity to the ESRS
Gateway.
The system is not
registered with an ESRS
Gateway and will not send
Alerts to EMC for
monitoring. Contact your
Support \ Sales
representative to get an
EMC ESRS support
package.
ESRS has a limit of
receiving up to 200 alerts
per 8 hours. The limit has
been reached, so no ESRS
messages will be sent in the
following 8 hours.
Check the network links
between the affected SDS
and SDC
Check the network links
between the affected SDC
and SDS IP addresses.
Check the network links
between the affected SDC
and all SDSs.
Check the network links
between all SDCs and the
affected SDS.
311

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents