Server Factory Reset and Power Operations
Verify the status of the system hardware, storage controller, and disks - 13G
servers
Dell EMC VxFlex Ready Node AMS User Guide
328
a. Select Processor Settings.
b. In the System BIOS Settings--Processor Settings pane, verify the
following parameter values:
Virtualization Technology = Enabled
l
Number of Cores Per Processor = All
l
c. Click Back to return to the System BIOS Settings screen.
8. Configure boot settings,:
a. Select Boot Settings.
b. In the System Boot Settings--Boot Settings pane, verify that Boot Mode
is set to BIOS (13G) or UEFI (14G).
c. Select the BIOS Boot Settings link.
d. In the System BIOS Settings--Boot Settings--BIOS Boot Settings pane,
verify that:
In the Boot Sequence list, Hard drive C: appears as the first item.
l
In the Hard-Disk Drive Sequence list, the SATADOM-ML 3SE (13G) or
l
BOSS (14G) device appears as the first item.
e. Click Back twice to return to the System BIOS Settings screen.
9. Configure integrated devices:
a. Select Integrated Devices.
The System BIOS Settings--Integrated Devices screen appears.
b. Set SR-IOV Global Enable to Enabled.
c. Verify that the Internal USB Port parameter is set to Off.
d. Click Back to return to the System BIOS Settings screen.
10. From the System BIOS Settings screen, click Finish, Yes, and then OK to
return to the System Setup Main Menu screen.
11. Select Finish to exit the BIOS and apply all settings post boot.
Results
The iDRAC IP and server BIOS address configuration is complete.
Use the following procedure to verify the status of the system hardware, storage
controller, and disks in a VxFlex Ready Node 13G server.
Before you begin
Ensure that you know:
The IP address of the iDRAC port
l
The username and password for the iDRAC portal (default username and password
l
are root and password)