Alert Message in
Alert Message in
VxFlex OS GUI
REST
Physical Disk state
PHYSICAL_DRIVE_
is erroneous (Hot
HOT_SPARE
Spare)
The Physical Disk is
PHYSICAL_DRIVE_
not being used by
NOT_IN_USE
the system
SSD lifespan is over
PHYSICAL_DRIVE_
endurance threshold
ENDURANCE_USE
D_ABOVE_THRESH
OLD
The Physical Disk
PHYSICAL_DRIVE_I
temperature has
NVALID_TEMPERA
exceeded the
TURE
configured
threshold
The Physical Drive's
PHYSICAL_DRIVE_I
cache is not disabled
NVALID_PD_CACH
E_POLICY
Device was
DEVICE_SHOULD_
requested to use as
USE_AS_DAS_CAC
DAS Cache but it is
HE_BUT_IT_IS_NO
not
T
The Logical Disk
LOGICAL_DISK_INV
read policy is not set
ALID_READ_AHEAD
to "Read-Ahead"
_POLICY
The Logical Disk IO
LOGICAL_DISK_INV
policy is not
ALID_WRITE_BACK
Configured properly
_POLICY
(Write-Back)
Logical Disk access
LOGICAL_DISK_INV
mode is not set to
ALID_ACCESS_MO
"Read-Write"
DE
The Logical Disk
LOGICAL_DISK_INV
RAID level is not set
ALID_RAID_LEVEL
to RAID0
Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
SNMP Trap
Storage_Controller.
Physical_Drive.HOT
_SPARE
Storage_Controller.
Physical_Drive.NOT
_IN_USE
Storage_Controller.
Physical_Drive.Endu
rance_Used_Above
_Threshold
Storage_Controller.
Physical_Drive.INVA
LID_TEMPERATUR
E
Storage_Controller.
Physical_Drive.INVA
LID_PD_CACHE_P
OLICY
Storage_Controller.
Physical_Drive.Devi
ce_Should_Use_As
_Das_Cache_But_It
_Is_Not
Storage_Controller.
Logical_Disk.INVALI
D_READ_AHEAD_P
OLICY
Storage_Controller.
Logical_Disk.INVALI
D_WRITE_BACK_P
OLICY
Storage_Controller.
Logical_Disk.INVALI
D_ACCESS_MODE
Storage_Controller.
Logical_Disk.INVALI
D_RAID_LEVEL
Alert Code
Severity
(for ESRS)
SIO06.01.000
3 (Error)
0002
SIO06.01.000
3 (Error)
0003
SIO06.01.000
5 (Critical) Replace the SSD device.
0004
SIO06.01.000
5 (Critical)
0005
3 (Error)
SIO06.01.000
3 (Error)
0006
SIO06.01.000
3 (Error)
0007
SIO06.02.000
3 (Error)
0001
SIO06.02.000
3 (Error)
0002
SIO06.02.000
5 (Critical) Access the storage controller
0003
SIO06.02.000
3 (Error)
0004
Dell EMC VxFlex Ready Node AMS User Guide
SNMP Trap Support
Recommended Action
Errors have been detected on
a spare Physical Disk.
Replace the Physical Disk.
Access the storage controller
and configure the disk.
Ensure that the server and its
environment are properly
cooled. Ensure that the
internal chassis fans are
working, and that there is
adequate airflow.
Disable the Physical Drive
physical cache. Note: This
may cause DI issues in power
cycle scenarios.
Access the storage controller
and change the Logical Disk's
read policy to "Read Ahead".
Check the Raid controller
battery status, a fault in the
battery will impact the Write-
Back functionality.
and change the logical disk's
access mode to "Read-
Write".
The RAID type is set in the
storage controller is
incorrect. Access the storage
controller, verify that the
Logical Disk does not contain
any data that is not backed-
up, destroy the Logical Disk,
313